Bryant 830SALegacy™ 80 Ultra-Low NOx Gas Furnace
80%
Single-Stage
CARB Certified
California Air Resources Board certified Ultra-Low NOx furnace. Clean emissions, simple venting, and proven reliability for Portland homeowners who want environmentally-friendly heating.

How the Bryant 830SA Solves Portland Heating Challenges
Clean emissions, simple installation, and proven reliability for Pacific Northwest homes
Clean Air for Portland
The 830SA meets California Air Resources Board (CARB) Ultra-Low NOx standards, producing 85% less nitrogen oxide emissions than standard furnaces. Perfect for environmentally-conscious Portland homeowners and required in air quality districts.
Reduce your home's environmental impact while meeting the strictest emissions standards in the nation.
Budget-Friendly Replacement
Replacing an old 60-70% AFUE furnace? The 830SA provides 80% efficiency at an entry-level price point. Non-condensing design means simple venting - no need for PVC exhaust modifications or condensate drains.
Lower upfront cost with standard B-vent metal flue - reuse your existing chimney venting.
Moderate Portland Winters
Portland averages only 35-50°F in winter with rare hard freezes. For homes with good insulation, 80% efficiency provides adequate heat at a fraction of the cost of 95%+ furnaces.
Save $2,000-4,000 on equipment and installation compared to high-efficiency condensing models.
Simple Proven Technology
Fixed-speed PSC blower and single-stage operation mean fewer electronic components to fail. Any HVAC technician can service this furnace - no specialized training required for complex variable-speed systems.
Lower repair costs and easier part availability for long-term reliability.
Bryant 830SA Key Features
Ultra-Low NOx Certified
Meets California Air Resources Board standards with 85% lower NOx emissions than standard furnaces.
80% AFUE Efficiency
Non-condensing design provides good efficiency without the complexity of condensing technology.
Standard Metal Venting
Uses traditional B-vent metal flue - no PVC piping or condensate drains required.
Fixed-Speed Blower
Simple, reliable PSC motor provides consistent airflow year after year.
Aluminized Steel Heat Exchanger
Durable heat exchanger backed by 20-year warranty provides long-term reliability.
Standard Thermostat Compatible
Works with any 24V thermostat - no smart controls required.
Technical Specifications
| Model Number | 830SA |
| Efficiency (AFUE) | 80% |
| Gas Valve Type | Single-Stage |
| Blower Motor | Fixed-Speed PSC |
| Heating Capacity | 40,000 - 120,000 BTU/h |
| Fuel Type | Natural Gas / LP Convertible |
| Ignition | Hot Surface Ignition |
| Venting | Category I Metal B-Vent |
| Heat Exchanger | Aluminized Steel |
| Emissions | CARB Ultra-Low NOx Certified |
Industry-Leading Warranty
Premium protection for premium equipment
- 20-Year Heat Exchanger - Aluminized steel heat exchanger covered for 20 years
- 10-Year Parts - All functional parts covered for 10 years
- Requires installation by Factory Authorized Dealer
- Product registration within 90 days required
Product Documentation
Official Bryant resources
Access the latest brochures, owner's manuals, installation guides, and warranty information directly from Bryant:
View Official DocumentsOpens Bryant.com - Always up-to-date documentation
Annual Savings vs. Older Furnaces
*Based on Portland average of 2,000 heating hours, $1.30/therm NW Natural gas. Actual savings vary.
Bryant 830SA Installation Throughout Portland Metro
Factory Authorized installation, repair, and maintenance service
Central Portland
Downtown, Pearl District, NW, NE, SE Portland, Sellwood, St. Johns
West Side
Beaverton, Tigard, Lake Oswego, West Linn, Hillsboro, Tualatin
East Side
Gresham, Happy Valley, Milwaukie, Oregon City, Clackamas
What Portland Homeowners Say
See why customers trust us for Bryant furnace installation
Frequently Asked Questions About the Bryant 830SA
What does Ultra-Low NOx mean for the 830SA furnace?
The 830SA meets California Air Resources Board (CARB) Ultra-Low NOx standards, producing 85% less nitrogen oxide (NOx) emissions compared to standard 80% AFUE furnaces. NOx contributes to smog and air pollution. While Oregon doesn't currently require low-NOx furnaces, the 830SA provides cleaner combustion for environmentally-conscious Portland homeowners. The special burner design and combustion chamber geometry achieve ultra-low emissions while maintaining 80% efficiency.
Does the 830SA require special venting like high-efficiency furnaces?
No, the 830SA is a non-condensing furnace that uses traditional Category I metal B-vent (also called Type-B vent). This is the same metal flue pipe that older furnaces use, often venting through an existing masonry chimney. Unlike 90%+ AFUE condensing furnaces that require PVC piping and condensate drains, the 830SA has simpler venting requirements. This makes installation easier and less expensive, especially in homes with existing metal venting systems.
How does the 830SA compare to Bryant's other 80% AFUE furnaces?
The Bryant Legacy lineup includes several 80% AFUE models. The 830SA is specifically designed for Ultra-Low NOx emissions compliance. The standard 800S and 810S models (also 80% AFUE) don't have the ultra-low NOx certification. The 830SA uses a more advanced burner system to reduce emissions while the 800S/810S prioritize lower cost. If you value cleaner air quality and don't need California compliance, the 800S or 810S may cost $200-400 less than the 830SA.
Ready to Install Your Bryant 830SA?
Get a free in-home estimate for Portland's cleanest-burning 80% AFUE gas furnace
Energy Trust of Oregon rebates available + Federal Tax Credits