1,280+ Positive Reviews | NATE Certified | Serving Portland Since 2008

(503) 698-5588

Serving Portland Since 2008

1,280 Five-Star Reviews

NATE Certified Technicians

Family-Owned & Operated

Preferred™ SeriesUltra-High Efficiency

Bryant 926SPreferred™ 96 Single-Stage Gas Furnace with InteliSense™

Efficiency

97%

Gas Valve

Single-Stage

Blower

Variable-Speed

Ultra-high-efficiency single-stage furnace with InteliSense™ remote monitoring delivers reliable warmth and maximum savings. Perfect for Portland's long, damp winters with exceptional 97% efficiency.

Bryant 926S Preferred™ 96 Single-Stage Gas Furnace with InteliSense™
97% AFUE

How the Bryant 926S Solves Portland Heating Challenges

Engineered for the Pacific Northwest's unique climate - from long wet winters to drafty older homes

Portland's Long Wet Winters

Portland averages 154 rainy days per year, with temperatures hovering between 35-50°F for months. The 926S delivers consistent warmth with ultra-high 97% efficiency, while the variable-speed blower adjusts airflow for even temperatures.

Maintains comfortable 70°F warmth with excellent efficiency even during Portland's coldest winter days.

Older Portland Craftsman Homes

Portland's beautiful 1920s-1940s Craftsman homes often have original ductwork and drafty areas. The 926S's variable-speed blower adjusts airflow continuously, providing better air distribution and preventing cold spots.

Even heating throughout multi-story homes with challenging layouts and older insulation.

Rising NW Natural Gas Bills

With NW Natural rates increasing, 97% AFUE means only 3 cents of every dollar is wasted up the flue. An 80% furnace wastes 20 cents of every dollar - that adds up to $550-800/year in savings.

Save $600-900 annually compared to an 80% AFUE furnace on Portland's average 2,000 heating hours.

Portland Power Outages

Winter storms knock out power across Portland Metro. While the 926S needs electricity, its ultra-efficient operation means lower runtime and less fuel consumption - stretching your gas supply during emergencies.

Variable-speed operation uses 50% less electricity than standard PSC motors, reducing backup generator load.

Bryant 926S Key Features

Single-Stage Gas Valve

Reliable single-stage operation delivers consistent full-capacity heating when needed, paired with ultra-high 97% efficiency.

InteliSense™ Remote Monitoring

Enables your HVAC contractor to remotely monitor system performance, diagnose issues, and schedule maintenance proactively.

Variable-Speed ECM Blower

Electronically commutated motor provides whisper-quiet operation and 50% lower electrical consumption than standard motors.

Two-Stage Heat Exchanger

Primary aluminized steel + secondary stainless steel extracts maximum heat from combustion gases for 97% efficiency.

Bryant Connex™ Compatible

Works with Bryant's smart thermostat for remote access, scheduling, and energy tracking via smartphone.

WhisperQuiet™ Design

Fully insulated cabinet with isolated blower assembly - quieter than most refrigerators.

Technical Specifications

Model Number926S
Efficiency (AFUE)97%
Gas Valve TypeSingle-Stage
Blower MotorVariable-Speed ECM
Heating Capacity40,000 - 120,000 BTU/h
Fuel TypeNatural Gas / LP Convertible
IgnitionHot Surface Ignition
VentingPVC, ABS, or CPVC (2" or 3")
Heat ExchangerAluminized Steel Primary + Stainless Secondary
CabinetDuraGuard Plus™ protection

Industry-Leading Warranty

Premium protection for premium equipment

  • Lifetime Heat Exchanger - Both primary and secondary heat exchangers covered for life
  • 10-Year Parts - All functional parts covered for 10 years
  • Requires installation by Factory Authorized Dealer
  • Product registration within 90 days required

Product Documentation

Official Bryant resources

Access the latest brochures, owner's manuals, installation guides, and warranty information directly from Bryant:

View Official Documents

Opens Bryant.com - Always up-to-date documentation

Annual Savings vs. Lower Efficiency Furnaces

vs. 80% AFUE FurnaceSave $600-900/year
vs. 90% AFUE FurnaceSave $230-375/year
vs. 92% AFUE FurnaceSave $165-275/year

*Based on Portland average of 2,000 heating hours, $1.30/therm NW Natural gas. Actual savings vary.

Bryant 926S Installation Throughout Portland Metro

Factory Authorized installation, repair, and maintenance service

Central Portland

Downtown, Pearl District, NW, NE, SE Portland, Sellwood, St. Johns

West Side

Beaverton, Tigard, Lake Oswego, West Linn, Hillsboro, Tualatin

East Side

Gresham, Happy Valley, Milwaukie, Oregon City, Clackamas

What Portland Homeowners Say

See why customers trust us for Bryant furnace installation

Frequently Asked Questions About the Bryant 926S

What is InteliSense™ technology on the Bryant 926S?

InteliSense™ enables your HVAC contractor to remotely monitor the 926S's performance, diagnose issues, and schedule maintenance proactively. This technology provides real-time alerts for potential problems, allowing for preventive maintenance before breakdowns occur. Your contractor can access system data remotely, reducing service calls and improving system reliability throughout Portland's heating season.

How does the 926S compare to two-stage furnaces for Portland homes?

The 926S uses a single-stage gas valve but achieves exceptional 97% AFUE efficiency - matching or exceeding many two-stage models. While two-stage furnaces provide more gradual temperature control, the 926S's variable-speed blower still delivers even airflow and quiet operation. For Portland's mild winters where the furnace runs frequently but not continuously, the 926S offers excellent value with top-tier efficiency at a lower price point than two-stage models.

What's the difference between the Preferred 926S and two-stage 926T?

Both achieve similar efficiency (926S: 97% AFUE, 926T: 96.7% AFUE) and feature variable-speed ECM blowers with InteliSense™ monitoring. The key difference is the gas valve: the 926S fires at full capacity when heating is needed, while the 926T can operate at 65% for mild weather. The 926S offers simpler, proven single-stage reliability with exceptional efficiency, making it an excellent choice for homeowners who prioritize high AFUE ratings and value.

Ready to Install Your Bryant 926S?

Get a free in-home estimate for this ultra-high-efficiency furnace

Energy Trust of Oregon rebates up to $1,000 + Federal Tax Credits available

Our Portland Metro Locations

Portland

4409 SE 24th Ave, Suite 35

Portland, OR 97202, USA

Milwaukie

14913 SE Kellogg Ave

Milwaukie, OR 97267, USA

Happy Valley

8305 SE Monterey Ave #220J

Happy Valley, OR 97086

Licensed
Bonded
Insured
NATE Certified
BBB A+
Financing Available
100% Satisfaction
24/7 Service