1,280+ Positive Reviews | NATE Certified | Serving Portland Since 2008

(503) 698-5588

Serving Portland Since 2008

1,280 Five-Star Reviews

NATE Certified Technicians

Family-Owned & Operated

Preferred™ SeriesHigh Efficiency

Bryant 926TPreferred™ 96 Two-Stage Gas Furnace with InteliSense™

Efficiency

96.7%

Gas Valve

Two-Stage

Blower

Variable-Speed

High-efficiency two-stage furnace with InteliSense™ remote monitoring delivers exceptional comfort and reliability. Perfect for Portland's long, damp winters with precise two-stage temperature control.

Bryant 926T Preferred™ 96 Two-Stage Gas Furnace with InteliSense™
96.7% AFUE

How the Bryant 926T Solves Portland Heating Challenges

Engineered for the Pacific Northwest's unique climate - from long wet winters to drafty older homes

Portland's Long Wet Winters

Portland averages 154 rainy days per year, with temperatures hovering between 35-50°F for months. The 926T's two-stage gas valve runs at 65% capacity most of the time, providing consistent warmth without the temperature swings of single-stage furnaces.

Maintains comfortable 70°F warmth even as outdoor temps fluctuate between freezing nights and 50°F afternoons.

Older Portland Craftsman Homes

Portland's beautiful 1920s-1940s Craftsman homes often have original ductwork and drafty areas. The 926T's variable-speed blower adjusts airflow continuously, providing better air distribution and preventing cold spots.

Even heating throughout multi-story homes with challenging layouts and older insulation.

Rising NW Natural Gas Bills

With NW Natural rates increasing, 96.7% AFUE means only 3.3 cents of every dollar is wasted up the flue. An 80% furnace wastes 20 cents of every dollar - that adds up to $500-750/year in savings.

Save $550-850 annually compared to an 80% AFUE furnace on Portland's average 2,000 heating hours.

Portland Power Outages

Winter storms knock out power across Portland Metro. While the 926T needs electricity, its ultra-efficient operation means lower runtime and less fuel consumption - stretching your gas supply during emergencies.

Variable-speed operation uses 50% less electricity than standard PSC motors, reducing backup generator load.

Bryant 926T Key Features

Two-Stage Gas Valve

Operates at 65% capacity for mild weather and 100% for extreme cold - reducing temperature swings and improving efficiency.

InteliSense™ Remote Monitoring

Enables your HVAC contractor to remotely monitor system performance, diagnose issues, and schedule maintenance proactively.

Variable-Speed ECM Blower

Electronically commutated motor provides whisper-quiet operation and 50% lower electrical consumption than standard motors.

Two-Stage Heat Exchanger

Primary aluminized steel + secondary stainless steel extracts maximum heat from combustion gases for 96.7% efficiency.

Bryant Connex™ Compatible

Works with Bryant's smart thermostat for remote access, scheduling, and energy tracking via smartphone.

WhisperQuiet™ Design

Fully insulated cabinet with isolated blower assembly - quieter than most refrigerators.

Technical Specifications

Model Number926T
Efficiency (AFUE)96.7%
Gas Valve TypeTwo-Stage
Blower MotorVariable-Speed ECM
Heating Capacity40,000 - 120,000 BTU/h
Fuel TypeNatural Gas / LP Convertible
IgnitionHot Surface Ignition
VentingPVC, ABS, or CPVC (2" or 3")
Heat ExchangerAluminized Steel Primary + Stainless Secondary
CabinetDuraGuard Plus™ protection

Industry-Leading Warranty

Premium protection for premium equipment

  • Lifetime Heat Exchanger - Both primary and secondary heat exchangers covered for life
  • 10-Year Parts - All functional parts covered for 10 years
  • Requires installation by Factory Authorized Dealer
  • Product registration within 90 days required

Product Documentation

Official Bryant resources

Access the latest brochures, owner's manuals, installation guides, and warranty information directly from Bryant:

View Official Documents

Opens Bryant.com - Always up-to-date documentation

Annual Savings vs. Lower Efficiency Furnaces

vs. 80% AFUE FurnaceSave $550-850/year
vs. 90% AFUE FurnaceSave $220-350/year
vs. 92% AFUE FurnaceSave $150-250/year

*Based on Portland average of 2,000 heating hours, $1.30/therm NW Natural gas. Actual savings vary.

Bryant 926T Installation Throughout Portland Metro

Factory Authorized installation, repair, and maintenance service

Central Portland

Downtown, Pearl District, NW, NE, SE Portland, Sellwood, St. Johns

West Side

Beaverton, Tigard, Lake Oswego, West Linn, Hillsboro, Tualatin

East Side

Gresham, Happy Valley, Milwaukie, Oregon City, Clackamas

What Portland Homeowners Say

See why customers trust us for Bryant furnace installation

Frequently Asked Questions About the Bryant 926T

What is InteliSense™ technology on the Bryant 926T?

InteliSense™ enables your HVAC contractor to remotely monitor the 926T's performance, diagnose issues, and schedule maintenance proactively. This technology provides real-time alerts for potential problems, allowing for preventive maintenance before breakdowns occur. Your contractor can access system data remotely, reducing service calls and improving system reliability throughout Portland's heating season.

How does the 926T's two-stage operation benefit Portland homeowners?

The 926T runs at 65% capacity most of the time during Portland's mild 35-50°F winters, providing consistent heat without temperature swings. It only ramps to 100% during extreme cold snaps. This two-stage operation reduces cycling, saves energy, and maintains more even temperatures throughout your home - especially important in drafty older Portland homes where single-stage furnaces create hot/cold cycles.

What's the difference between the Preferred 926T and Evolution 986T?

Both have 96.7% AFUE and two-stage operation, but the Evolution 986T includes Perfect Heat® technology with more advanced temperature control algorithms and Evolution Connex™ integration. The 926T uses InteliSense™ for remote monitoring and works with Bryant's standard Connex controls. The 926T offers excellent value for homeowners who want high efficiency and two-stage comfort without Evolution series premium features.

Ready to Install Your Bryant 926T?

Get a free in-home estimate for this high-efficiency two-stage furnace

Energy Trust of Oregon rebates up to $1,000 + Federal Tax Credits available

Our Portland Metro Locations

Portland

4409 SE 24th Ave, Suite 35

Portland, OR 97202, USA

Milwaukie

14913 SE Kellogg Ave

Milwaukie, OR 97267, USA

Happy Valley

8305 SE Monterey Ave #220J

Happy Valley, OR 97086

Licensed
Bonded
Insured
NATE Certified
BBB A+
Financing Available
100% Satisfaction
24/7 Service