AC Fan Not Working? Restore Airflow in Your Portland Home
No airflow from the vents means warm rooms, rising humidity, and a compressor that could overheat. Use this guide to tackle the most common indoor fan failures, learn which quick fixes you can safely attempt, and know when it is time to call the pros.
Trusted across Portland, Beaverton, Lake Oswego, Tigard, and the entire metro area.

Owner & Lead HVAC Technician
Quick Answer
Fan Stopped? Start with These Checks
If the AC fan is not working, begin with safe DIY steps: verify thermostat settings, replace the air filter, check for tripped breakers, and clear condensate drains. Many issues are tied to failed capacitors or motors and should be left to professionals. The checklist below guides you through the must-do items before scheduling service.
Confirm the thermostat is set to COOL and the fan mode is AUTO (not OFF).
Replace or clean the air filter to remove airflow restrictions.
Inspect supply vents to make sure furniture or rugs are not blocking airflow.
Check the electrical panel for a tripped breaker and inspect the condensate safety switch (float switch).
Look for ice on the indoor evaporator coil; if present, turn the system off and allow it to thaw.
Call Efficiency Heating & Cooling for blower motor, capacitor, or control board diagnostics.
Top Reasons AC Fans Fail in Portland Homes
Portland’s mix of river humidity, crawlspace installations, and long stretches of off-season downtime create unique challenges for AC blowers. Unlike desert climates where systems run constantly, our motors sit idle through winter, inviting corrosion and critters. Below you’ll find the ten most common issues our technicians repair across the metro area, along with repair costs and prevention tips.
Blown Blower Motor Capacitor
Just as the outdoor compressor relies on a capacitor, the indoor blower motor uses one to start and run. When the capacitor fails, the fan will not spin, and you may hear a faint hum from the air handler.
- •Symptoms: No airflow from vents, humming sound in the furnace or air handler cabinet.
- •Repair cost: $140-$320 in the Portland market depending on capacitor size and accessibility.
- •Prevention: Annual tune-ups catch weak capacitors before the summer rush.
Failed ECM or PSC Blower Motor
Variable-speed ECM motors are efficient but sensitive to power surges and moisture. PSC (permanent split capacitor) motors can seize after years of use or if bearings dry out.
- •Symptoms: Complete silence, burning smell, or motor starts then stops quickly.
- •Repair cost: $450-$1,100 depending on motor type and whether a matching module is needed.
- •Portland tip: Crawlspace furnaces are more prone to condensation and corrosion — add vapor barriers and dehumidification.
Clogged Air Filter or Return Duct
A severely clogged filter starves the blower motor of air, causing overheating that triggers the high-limit switch. Portland’s pollen, pet dander, and wildfire smoke season clog 1-inch filters rapidly.
- •Replace filters every 60 days; during wildfire smoke events, check monthly.
- •Consider upgrading to a 4-inch media cabinet to increase surface area and airflow.
Condensate Float Switch Triggered
Modern systems include a safety float switch that shuts off the fan when the condensate drain pan fills with water. Clogged drain lines from algae or Portland’s ever-present moss cause frequent trips.
- •Look for water in the secondary drain pan. If the float is raised, clear the drain with a wet/dry vac.
- •Add a maintenance tablet or schedule yearly drain cleaning to prevent microbial buildup.
Frozen Evaporator Coil
A coil covered in frost blocks airflow, so the fan may run but nothing blows through the ducts, or safety controls may stop the fan altogether. Causes include low refrigerant, dirty filters, or blocked returns.
- •Turn the system off and run just the fan to thaw the coil.
- •After thawing, call for service to address the underlying cause or the freeze will return.
Faulty Fan Relay or Control Board
The thermostat sends a low-voltage signal to the control board, which energizes the fan relay. Failing relays, burnt traces, or bad connections stop the fan even when the thermostat calls for cooling.
- •Repair cost: $250-$750 depending on board complexity.
- •Install surge protection to guard sensitive electronics from PGE grid fluctuations.
Thermostat Fan Settings
Thermostats set to ON run the fan continuously, but if the fan mode is set to OFF or the thermostat is on HEAT, the fan may never start for cooling. Dead batteries also prevent the fan relay signal.
- •Replace thermostat batteries every 12 months.
- •Smart thermostats should be rebooted after firmware updates to clear lockups.
Ductwork Issues and Disconnected Runs
In Portland’s older homes, flexible ducts in crawlspaces can collapse or disconnect after rodent activity or a heavy person stepping on them. The fan may be running, but air never reaches rooms.
- •Inspect accessible ducts for kinks or disconnections and reseal with mastic (never duct tape).
- •Professional duct sealing and support straps prevent recurrent issues.
Limit Switch or Safety Control Trips
Overheating limit switches, blower door interlocks, and fusible links inside the furnace cabinet can open and stop the fan for safety. Causes include clogged filters, restricted supply vents, or motor overheating.
- •If a safety trips repeatedly, schedule service; resetting without fixing the root cause can lead to fire hazards.
Aging Blower Wheel Packed with Dust
Dust and microbial buildup on blower wheel blades reduce airflow dramatically. Eventually the motor cannot overcome the imbalance and shuts off. Portland’s high humidity encourages sticky dust.
- •Professional blower wheel cleaning costs $180-$350 and includes wheel removal, cleaning, and balancing.
- •Combine with duct cleaning and IAQ upgrades to maintain airflow.
Prevent Fan Failures Before Summer Hits
Call If You Notice These Warning Signs
Burning smell coming from the vents or furnace cabinet.
Breaker trips whenever the fan tries to start.
Visible ice on refrigerant lines or evaporator coil.
Fan starts, stops, and starts again within seconds (short cycling).
AC Fan Repair FAQs for Portland Homeowners
Keep Cool Airflow Moving All Summer
Whether your fan stopped during the first hot day of June or during wildfire season, our team restores airflow fast and checks every safety control to keep your family comfortable. Call now to schedule service with Portland’s highest-rated HVAC experts.